Gas Solenoid Valve

Gas Solenoid Valve GSAV.... .2R GSAV... .2L

MPA 41xx V1

Automatic burner control for one-stage gas burners, Free configurable program sequence

Elektrogas Gas Safety solenoid valve VMR6-Rp2

Model: VMR6-Rp2 A safety shutting device using auxiliary power supply. Version: Fast opening and fast closing Supply voltage: 230 V AC Frequency: 50/60 Hz Power: 20 VA Current: max. 0.5 A Connection: Rp 2 “ Inlet pressure: 360 mbar C/O time: max. 1 sec Protection Class: IP 54 Ambient temp.: -15 °C … 60 °C Weight: 5.7 kg

FIDA 8Kv 20mA ignition transformer

Similar products : 8/20 CM, 8/30 CM, 8/10 CM, 5/18PM, 6/20 PM, 10/20 CM, 8/20 CM, 12/20 CM, 10/30 CM, 6/25 PM, 8/20PM, 8/30PM

DUNGS MultiBloc MBE Valve VB-125 (274665)

The MBE multifunctional control combines the housing with two safety shutoff valves (ValveBody) and two electronic drives (ValveDrive) to actuate the safety valves and, optionally, to control the outlet pressure. The MBE is recommended for industrial and commercial heating applications that require two safety shutoff valves in series. The MBE is suitable for natural gas, vaporized propane or butane, air, 100% hydrogen, biogas up to max. 1% vol. H2S, and other inert gases.

DUNGS DMV-D 5080/11 eco (256360)

Max. Operating pressure: 500 mbar Nominal diameter: DN 65 - DN 125

filter FG 60125-FT DN125

Function : Filters can be installed in gas internal and compressed airpiping to protect subsequent valves. The filter element is composed of polypropylene non-woven fabric with a bore diameter of ≤ 50 μm. Dust, debris, rust and other solid companions and contaminants in the gas can be trapped by a non-woven cloth. When the dust collection capacity is exceeded or the pressure difference is too large, the filter loses its protection function. Install : Ot Note the direction of the air flow identified by the arrow on the filter housing. Consider the space required to replace the filter element. A vertically mounted filter cover facilitates the cleaning of the filter housing. Air tightness shall be checked after the installation. pay attention to! Not between hardened brick walls, concrete walls, floors, and filters Have direct contact. Replace the filter element : - Replace it at least once a year - When the differential pressure is 100% higher than the new filter element - When the pressure difference reaches a maximum of 50 mbar

DUNGS coil Mag.Nr.280 (213796)

Type:Mag.Nr.280 Art.Nr.213796 ~230 VAC 50-60Hz 60W IP54

DUNGS ignition transformer DEZ200 2x14kv (252114)

The DUNGS DEZ are electronic high-performance ignition transformers with high-frequency oscillation technology. Compared with conventional inductive ignition transformers, the DEZ are much smaller and lighter. Designs for one or two ignition electrodes are available in different voltage versions. SEO Model is the single electrode model. SEO versions are to be used when both ignition of the burner & flame monitoring via flame rod (ionization) are done with the same electrode. Application For oil and gas burners, ignition takes place, depending on design, with one ignition electrode against the burner mass or with two ignition electrodes between the electrodes. The DEZ ignition transformers are available in two versions: either (DEZ 1xx) with a high-voltage output for ignition against the burner mass or (DEZ 2xx) with two high-voltage outputs for ignition between the electrodes. For use in burner systems in which ignition and ionization flame monitoring takes place via a common electrode, the “SEO” versions must be used. Transformers for two electrodes are available upon request

DUNGS Pressure switch GAO-A4-4-3

Description The GAO-, GMH- and GML-A4… ventless pressure switches are adjustable pressure switches for automatic burner controls. These pressure switches are suitable for making and/or breaking a circuit when the medium pressure changes relative to the set point. The set point can be set in the field by an adjustable dial with an integrated scale. Test nipple integrated in metal housing to verify set point. Application : The GAO-, GMH-, and GML-A4… pressure switch is recommended for industrial and commercial heating, ventilation and air-conditioning systems. The GAO-, GMH-, and GML-A4… pressure switch is suitable for dry natural gas, propane, butane, air and other inert gases. Suitable for up to 0.1 % by volume, dry H2S.A “dry” gas has a dew point lower than +15 °F and its relative humidity is less than 60 %.

< 1234...25 >