Contact us

If you are interested in cooperation, please contact us immediately, we will give you feedback as soon as possible!


Weishaupt filter WF 510-1

Weishaupt filter WF 510-1 Category: Burner accessories WF 510-1:It is a high-efficiency fuel filtration equipment made by the German Weishaupt brand. Model: WF 510-1 Structural form: adopts a quick-release filter cartridge design, supporting single-core or multi-core parallel connection (common 3-core/5-core configuration). Functions: fuel purification, corrosion resistance design, and maintenance convenience.

Weishaupt controller W-FM 20 V3.11

Weishaupt controller W-FM 20 V3.11 W-FM 20 V3.11 is a core control device for gas burners produced by Weishaupt, which is mainly used to regulate the combustion process and monitor the operating status. Core functions ‌Microprocessor control‌: Automatic control of all functions of the burner through a built-in microprocessor. ‌ ‌Safety Monitoring‌: Monitor combustion status in real time to ensure safe operation. ‌Data Bus Interface (eBUS): Supports data communication with other devices. ‌Solbaric valve leak detection device‌: built-in function to detect leakage in gas pipelines. Applicable model Suitable for the following Viso burners: ‌Gas type‌: WG10 (proportional adjustment), WG20 (proportional adjustment), WG30, WG40. ‌Fuel type‌: WL30 (dual-segment fire), WL40 (dual-segment fire)‌.

Weishaupt Burner Programmer W-FM25 V2.0(D-73660)

Weishaupt Burner Programmer W-FM25 V2.0(D-73660) The W-FM25 V2.0 (D-73660) is a combustion management controller developed by DUNGS, mainly used for the automatic control and safety monitoring of gas/oil burners. This controller adopts microprocessor technology and features high-precision control, safety protection, and fault diagnosis capabilities, making it suitable for industrial and commercial combustion systems. Power Supply Voltage: 230V AC, 50/60Hz Power Consumption: Approximately 12W Protection Class: IP40 Operating Temperature: -20°C to +60°C Main Functions: (1) Combustion Control Function Automatic Ignition Control: Controls ignition transformers, solenoid valves, and other actuators to achieve safe ignition. Flame Monitoring: Detects flame status through ionization electrodes or UV flame detectors to ensure combustion safety. Operation Mode Management: Supports single-stage, two-stage, or proportional combustion modes. Pre-Blowout & Post-Blowout: Ensures no residual flammable gas in the furnace before and after combustion, enhancing safety. (2) Safety Protection Function Lockout Protection: Automatically locks the burner in case of faults to prevent dangerous operation. Safety Time Control: Sets SZA (Safety Wait Time) to ensure the burner restarts under safe conditions. (3) Human-Machine Interaction & Debugging Function LCD Display: Shows operating status, fault codes, parameter settings, etc. Key Operation: Supports manual debugging, parameter adjustment, and reset operations. eBUS Communication: Supports communication with upper-level machines (such as PLCs, building automation systems) for remote monitoring. (4) Compatibility & Expandability Compatible with mainstream burner brands such as Weishaupt, Riello, and Baltur. Can be used with peripheral devices such as pressure switches, gas valve groups, and temperature controllers.

Weishaupt burner ion line

Weishaupt burner ion line Burner ion line is a key component for flame detection and is usually used in conjunction with ionizing electrodes (flame sensors). It determines whether the flame exists by detecting the ionization current of the flame during combustion to ensure the safe operation of the burner. Main functions ‌one.Flame Detection‌ When burning, the flame generates a weak ionization current, and the ion wires transmit this signal to the programmer (such as W-FM25 V2.0). The program controller determines whether the flame is burning normally by analyzing the current magnitude. ‌two.Safety protection‌ If the flame goes out unexpectedly (such as gas interruption, strong air interference, etc.) and the ion line cannot detect the current, the program controller will immediately cut off the gas supply to prevent the risk of gas leakage or explosion. ‌three.Compatibility‌ Suitable for mainstream burner brands such as Weishaupt, Riello, Baltur. Structural characteristics of ion wires: ‌Conductor: Usually high-temperature resistant copper core wire is used to ensure stable signal transmission. ‌Insulation layer‌: High temperature resistant silicone or ceramic material to prevent high temperature damage. ‌Shielding layer‌: Some models have metal shielding layers to reduce electromagnetic interference (EMI). ‌Connection terminal‌: Standard plug or screw terminal for easy connection of program controller or electrodes.

Weishaupt burner LCD display AM25 V1.0(D-73660)

Weishaupt burner LCD display AM25 V1.0(D-73660) AM25 V1.0 (D-73660)‌ is a ‌LCD display (LCD) module designed for burner control systems. It is usually used with Wisso Programming Controllers (such as W-FM25 V2.0) for human-computer interaction, parameter setting and operating status monitoring. ‌Supply voltage: 24V DC (usually provided by the program controller) ‌Protection Level‌: IP40 (dust-proof, not waterproof) Main functions ‌(1) Operation status display Display the burner operation mode‌‌ in real time (standby, ignition, operation, fault, etc.). Displays the flame status (with/no fire), temperature/pressure value (such as boiler water temperature, flue gas temperature, etc.). Provide ‌fault codes‌ (such as E01 ignition failure, E02 ignition shutdown, etc.) to facilitate rapid diagnosis of problems. ‌(2) Parameter setting and debugging ‌ Adjust burner parameters by pressing the keys, such as: ‌ignition time‌‌ pre-purging time‌ ‌Gas valve opening‌ (proportional adjustment burner) Temperature/pressure setting value Supports ‌manual/automatic mode switching, which is convenient for maintenance and testing. ‌(3) Security and Alarm Management Automatically record the fault history to help analyze burner operation problems. ‌(4) Communication interface ‌ Communication with the host computer (PLC, building control system) through ‌eBUS or Modbus, realizing remote monitoring and data transmission.

Weishaupt ignition transformer W-ZG 01-V

Weishaupt ignition transformer W-ZG 01-V W-ZG01/V is a special accessories for Weishaupt burners in Germany. It is a high-pressure ignition device designed for gas burners. It is mainly used in industrial boilers, furnaces and heating equipment to ignite gas mixtures by generating high-voltage electric sparks. Output voltage‌: double-stage 2×9KV high-voltage output‌. ‌Output current‌: 20mA, suitable for WG/WL series gas burners‌. ‌Power input‌: 230V/50-60Hz, power of 100VA‌. Adaptive models: Weishaupt WG5/WG10/WG20 series gas burners, WL5/WL10 series low-nitrogen burners and WGL series oil and gas dual-purpose burners. Functional Features: one.Ignition mechanism: High-voltage pulse generation: Through the principle of electromagnetic induction, the 230V input voltage is boosted to 9kV, creating an electric spark between the ignition electrodes, breaking down the gas-air mixture. two.Safety protection Overload protection: Built-in current limiting circuit, which automatically cuts off the power supply when the output is short-circuited or the load is abnormal to prevent equipment from being damaged. three.Control interface Signal input: supports dry contact signals of the burner controller to realize the linkage control of ignition and flame detection.

Weishaupt 600mm ionization cable(21710417022)

Weishaupt 600mm ionization cable(21710417022) Weishaupt ionization cable 21710417022 (600mm) is a flame monitoring component designed for gas burners to transmit ionic currents to detect the presence of flames and ensure the safe operation of the burner. The cable works through the ionization effect: when the flame is formed, high-temperature gas is ionized to generate ionic current, and the cable transmits this current signal to the burner controller (such as Weishaupt CU500) to achieve real-time flame monitoring. Operating voltage: Usually 24V DC (compatible with Weishaupt burner controller), maximum withstand voltage 1000V AC. Current capacity: ionic current range 0.1~2mA, matching the burner flame detection sensitivity. Length and interface: 600mm standard length, equipped with M8 or M12 waterproof connectors (such as Weishaupt dedicated interface) on both ends, supporting quick plug-in and unplug. ‌Functional Features‌: Used to detect the ionization signal of the burner flame and feed back to the control system to achieve flame out protection. The cable structure is deeply compatible with the Weishaupt burner ignition system (such as W-ZG series transformers). Application scenarios: Mainly equipped with Weishaupt gas/oil burners, such as WG/WL series industrial boiler equipment.

Weishaupt ignition electrode WG5-40 (23220014217)

Weishaupt ignition electrode WG5-40 (23220014217) Ignition electrode WG5-40 is a core ignition assembly designed for Weishaupt WG series gas burners, mainly used to generate high-voltage electric sparks to ignite fuel-air mixed gases. Adaptive model: WG5-40 gas burner‌. ‌Electrical characteristics‌: The working voltage is 220V, and it is required to be equipped with Weishaupt original ignition transformer‌. Core functions High-voltage discharge ignition: Combined with Weishaupt ignition transformers (such as W-ZG 01/V type), high-frequency electric sparks are generated at the electrode tip (breakdown voltage is about 7~9kV), and quickly ignite the fuel mixture emitted by the burner. Flame stability guarantee: Through precise electrode spacing design (standard 2.5mm, adjustable range 1.5~4mm), ensure the continuous stability of the arc and adapt to the rapid ignition requirements during the burner start-up stage. Protection Grade: IP65 dust-proof and waterproof design, which can work stably in humid, dusty or lightly splashed industrial environments. Operating voltage: adapted to the 2×9kV output of Weishaupt ignition transformer, maximum withstand voltage of 500V AC. Ignition frequency: usually 50~60Hz, matching the timing requirements of the burner controller. Main use scenario: WG5-40 compact gas burner (power range 43-2,390 MBTU/h).

< 1 >