VGS10.2..B2

It is mainly used in gas pipelines connected with forced blast burners. Standards & Certifications:

VGC10.4...A2*VGC11.3...A2

It is mainly used in gas pipelines connected with forced blast burners. Standards & Certifications:

151772-71

lt is suitable for pre-mixed combustion of condensing boilers and steam generatorsSuitable for hot water boiler, about 135-138m3/h Certifications:

151726-70

lt is suitable for pre-mixed combustion of condensing boilers and steam generatorsSuitable for hot water boiler, about 135-138m3/h Certifications:

150542-78

It is suitable for pre-mixed combustion of condensing boilers and steam generators Enhanced version, suitable for steam generator, about 80m3/h Certifications:

SIEMENS Servo motor SQM10.16102

SIEMENS Servo motor SQM10.16102 Servo motor SQM10.16102:It is an electric actuator for medium and large fuel or gas burner damper damper or air/fuel ratio control. The motor adopts cam control and gear clutch, and has internal and external position indication functions. Operating voltage: AC 220-240V, 50Hz (-15%/+10%); AC 220V, 60Hz (-15%/+10%); AC 110V, 50/60Hz (±6%). Switching Capacitor: The switching capacitance of the limit converter switch and auxiliary converter switch is 10(3)A, AC 24-250V. Installation location: any. Protection level: IP54. Weight: about 1.7kg. Power consumption: 9VA. Temperature range: -20"C-+70°C. Functions: Accurate control of angles, provide feedback signals, flexibly set switches, and adapt to various working conditions.

SIEMENS Ignition transformer ZM20-12

SIEMENS Ignition transformer ZM20-12 Ignition transformer ZM20-12:It is an ignition accessory designed for burners. Input voltage: 230V. Output voltage: 2*6kV. Output current: 20mA. Ignition frequency: 20% in 3min. Product number: 00426270. Main functions: Generate high-voltage ignition: transform the initial voltage, generate high-voltage electricity, connect the ignition electrode through the ignition cable, discharge, ignite the fuel, and complete the burner ignition procedure. Voltage conversion and isolation: It has voltage conversion function, which can convert the input low voltage into high voltage output, and also plays an electrical isolation role, ensuring safe isolation of the ignition system from other circuit parts, and improving system stability and safety. Stable ignition performance: It can achieve voltage stabilization to a certain extent, ensuring that the high voltage output is relatively stable, so that the ignition process is reliable and not affected by small fluctuations in the power grid voltage, ensuring that the burner can start stably and efficiently.

SIEMENS Electric valve actuator SAX619.03

SIEMENS Electric valve actuator SAX619.03 The actuator can be mounted directly on the valve without adjustment. Equipped with manual regulator, position indicator and LED status display, and optional auxiliary switches, potentiometers, functional modules, stem heating elements and other components. Rated thrust: 800N. Operating voltage: AC/DC24V. Control signal: DC0-10V, 4-20mA or 0-1000Ω. Main functions: precise control, valve position feedback, manual operation, status display, function expansion.

SIEMENS Comparison instrument RWF55.50A9

SIEMENS Comparison instrument RWF55.50A9 Comparison instrument RWF55.50A9:It is a controller dedicated to burners, mainly used to regulate the temperature or pressure in fuel or gas heaters. External dimensions: approximately 48x96x122mm, suitable for opening holes in the control cabinet panel. Housing material: consists of pressure-resistant and thermo-resistant plastic shell. Display method: It has 2 four-digit 7-segment monitors, which are used to display the measured value (red) and the set value (green). Power supply: Usually supports 110-240V voltage and frequency is 50/60Hz. Main functions: proportional adjustment, PID adjustment, multiple input interfaces, and setting value adjustment.

SIEMENS Servo motor SQN70.224A20

SIEMENS Servo motor SQN70.224A20 Servo motor SQN70.224A20:It is a damper actuator for burners, mainly used for damper baffle control or air/fuel ratio control for small and medium fuel or gas burners. Working voltage: AC230V, 50/60Hz. Power: 6VA. Protection level: IP54. External dimensions: approximately 117×66×90mm. Main functions: damper control, proportional adjustment, position indication, cam adjustment, switch settings.

SIEMENS Servo motor SQM50.480A2

SIEMENS Servo motor SQM50.480A2 Servo motor SQM50.480A2:It is a damper actuator for burners, mainly used for the damper baffle or air/fuel ratio control of medium and large-sized oil or gas burners. Working voltage: AC220V ± 15% to AC240V + 10%. Working frequency: 50/60Hz ± 6%. Power: 20VA. Protection grade: IP54. Temperature range: -20℃ to +60℃. Main functions: damper control, bidirectional rotation, gear clutch, position indication, multi-specification drive, and compatibility with controllers.

SIEMENS Servo motor SQN72.2A4A20BT

SIEMENS Servo motor SQN72.2A4A20BT Servo motor SQN72.2A4A20BT:It is a damper actuator for small and medium-sized fuel or gas burners, mainly used to control the damper baffle or gas and fuel valves to achieve the optimal fuel and combustion air mixture ratio. Operation time: 4.0S - 30S. Holding torque: 0.7Nm - 1.3 Nm. Power supply: Usually AC230V, 50/60Hz. Protection grade: It has certain protection capabilities, with a pressure-resistant and heat-resistant plastic housing that can adapt to certain environmental conditions. Main functions: Precise control, multiple connection methods, mechanical structure advantages, switch settings.

SIEMENS Control box RMG-M88.62C2

SIEMENS Control box RMG-M88.62C2 Control box RMG-M88.62C2:It is a microprocessor-based burner controller, mainly used to monitor one or more fire forced ventilation gas burners. Power supply voltage: AC 220 - 240V. Power supply frequency: 50 - 60Hz. Power consumption: 20VA. Safety Level: Level I. Size: Approximately 11.07cm x 6.45cm x 10.37cm. Weight: approximately 0.26Kg. Main functions: flame detection, air pressure monitoring, low voltage protection, status display, and sequential control.

SIEMENS Control box LME22.233C2

SIEMENS Control box LME22.233C2 Control box LME22.233C2:It can be used in burners, boilers and other equipment, suitable for fuel oil or gas fuel, and can monitor and control single-stage or two-stage forced ventilation gas or fuel oil/gas intermittent operation burners. It is suitable for small and medium capacity (up to 350kW) burners. Working voltage: AC 230V, -15%/+10%. Power consumption: 12VA. Protection grade: IP40. Operating temperature range: -20℃ to +60℃. Weight: about 160g. Functional features: flame monitoring, low voltage detection, air pressure monitoring, remote reset, status display, repeated start limit, precise timing control, intermittent operation control.

SIEMENS Controller LFL1.635

SIEMENS Controller LFL1.635 Controller LFL1.635:It is applicable to burners, boilers and other equipment, and can be used for fuel oil or gas fuel. It is mainly used for monitoring and controlling single-stage or two-stage forced ventilation gas or oil/gas intermittent operation burners with small and medium capacity (up to 350kW). Working voltage: AC 230V, -15%/+10%. Power consumption: 12VA. Protection grade: IP40. Working temperature range: -20℃ to +60℃. Weight: about 160g. Functional features: flame monitoring, low voltage detection, air pressure monitoring, remote reset, status display, repeated start limit, precise timing control, intermittent operation control.