Burner Accessories
Contact us
If you are interested in cooperation, please contact us immediately, we will give you feedback as soon as possible!
SIEMENS servo motor SQN72.2B4A20BT
SIEMENS servo motor SQN72.2B4A20BT SQN72.2B4A20BT: Mainly used for the control of damper blades in small and medium-sized oil/gas burners or for the adjustment of air-fuel ratio. Application field: It is an actuator of the SIEMENS burner control system, used in conjunction with burner controllers (such as LOA, LMO series) to achieve automatic regulation of the combustion process. Power supply specification: AC 230V ± 10%, 50/60Hz, with built-in overload protection and overheat shutdown function. Drive type: Bidirectional rotating synchronous motor. Core functions Damper adjustment: By rotating the damper blades, the combustion air flow is dynamically adjusted to be in sync with the fuel supply, ensuring maximum combustion efficiency. Air-fuel ratio control: In conjunction with a proportional-integral (PI) controller (such as the RWF40 module), it optimizes the air-fuel mixture ratio in real time, reducing CO and NOx emissions. Safety interlock: Equipped with limit switches and auxiliary contacts, when the damper exceeds the set range or the motor is overloaded, it triggers a shutdown signal and locks the burner operation.
SIEMENS power transformer AGG5.220
SIEMENS power transformer AGG5.220 AGG5.220 is an industrial-grade power transformer designed for burner control systems, especially suitable for SIEMENS LMV5 series electronic air/fuel ratio control systems. Electrical characteristics: Input voltage 230V 50-60Hz, triple output: 12Vac 1.2A (main control loop) + dual 12Vac 4.3A (drive loop), Operating temperature range is -20℃ to +70℃. Output type: DC 12V (isolated dual-channel). Power range: 103VA. Application scenario: Power supply to the control system. Interface type: Rast 5 connector. Typical Applications Burner control system: provides power for LMV51.100C2, LMV52.200B2 and other models of controllers, and is suitable for gas/fuel burners with thermal power of ≤10MW. Industrial Automation: As a backup power supply for distributed I/O modules such as ET 200S, or auxiliary power supply for PLC expansion modules such as SIEMENS 6ES7 series.
SIEMENS control box LMV37.410A2WH
SIEMENS control box LMV37.410A2WH Model: LMV37.410A2WH LMV37.410A2WH is a microprocessor-controlled combustion management system designed for medium and high power burners. The core functions include combustion process automation control, safety interlocking and air-fuel ratio optimization. Electrical characteristics: Supply voltage 230VAC±10%, frequency 50-60Hz Operating temperature range -20°C~60°C Mechanical characteristics: compact design, plastic housing, clamped mounting structure. Core functions Intelligent combustion control: Integrated eBUS communication protocol, support remote monitoring and parameter configuration With flame monitoring function, real-time feedback on combustion status Support proportional adjustment (PID control), air-fuel ratio accuracy ±2% Safety protection system: Dual-channel safety circuit design TSA (safe time monitoring) function, automatic fuel cutoff after timeout Device compatibility: Designed for Weishaupt burners (WM-L/G/GL series) Supporting servo motors, solenoid valves and other actuators Typical configuration: Fuel burner: WM-L10/L20/L30 Gas burner: WM-G10/G20/G30
RIELLO distributor (3013776) Category: Burner accessories This model is mainly used for gas or fuel distribution control. Core functions: Precise fuel distribution It adopts a modular design and can be adapted to Riello burners of different powers (such as the RS series), and accurately controls fuel flow through the regulating valve group. Efficient combustion support Works in conjunction with Riello burner technology to optimize combustion efficiency and reduce energy consumption. Industrial reliability Suitable for high-demand scenarios such as automobile manufacturing and rail transit, it has high temperature resistance and anti-interference design to ensure long-term and stable operation. Compatibility Extensions It can be used with Riello controllers (such as RMO503SE, MMI series) to achieve automated control, and supports multiple fuel types (natural gas, liquefied gas, etc.)
RIELLO distributor (3013776) Category: Burner accessories Core functions one.Fuel Distribution Control: Designed specifically for GULLIVER series burners (RG2/RG3/RG4S and other models), it realizes multi-channel precision distribution of fuel/gas. Built-in mechanical regulating valve group, supports intermittent operation mode, pre-purging time 12 seconds, and ignition waiting time 8 seconds. two.System compatibility: It is adapted to SIEMENS controller (AGQ3.1A27, 503SE and other models), and can be used with the GW/1G/2G models of PRESS series burners. Supports signal interaction with controllers such as RMO503SE, MG557/3, and meets the single-stage/dual-stage combustion needs. three.Industrial reliability: It is made of corrosion-resistant alloy material, with a working temperature range of -40℃~100℃, and a protection level of IP40, which is suitable for harsh environments such as boilers and drying lines.
SIEMENS control box LOK16.250A27
SIEMENS control box LOK16.250A27 LOK16.250A27 is an intelligent combustion controller specially designed for fuel burners by SIEMENS, and belongs to the core model of the LOK16 series. Core functions one.Multi-fuel control Designed for forced ventilation large and medium-sized burners, it supports fuel/gas multi-stage adjustment and proportional continuous adjustment mode, and the main voltage is compatible with AC220V-240V (±10%). two.Intelligent security monitoring Integrated self-test flame signal amplifier (silicon photodetector RAR9). Monitor flame signals in real time and can identify 16 types of faults such as detector failures, cable abnormalities, and false flames. Equipped with an air pressure sensor to realize closed-loop control of the damper baffle. three.Industrial reliability Protection level IP40 (prevent solid particles from invasion). Working temperature -20℃~+60℃. Frequency range: 50/60Hz.
Steinen oil mouth 0.60 60°S 0.60 60°S:A solid cone atomization nozzle designed for small and medium-sized fuel burners realizes efficient atomization and stable combustion of fuel, and is widely used in industrial boilers, furnaces and hot air furnaces and other equipment. Core functions: efficient combustion control, pressure regulation and stability, safety and reliability. Spray angle: 60° solid cone. Applicable fuels: diesel (EN 590), heavy oil (ISO 8217), biodiesel.
Steinen oil mouth 1.00 60°S 1.00 60°S:Solid cone atomizing nozzle designed for medium and high load fuel burners belongs to its classic "Dyna-Coin" series. This model achieves efficient atomization and stable combustion of fuel through precision mechanical processing and surface treatment processes, and is widely used in industrial boilers, furnaces and hot air furnaces and other equipment. Traffic: 1.00 GPH. Working pressure: inlet 1.0-1.4MPa; outlet 5-15mbar. Spray angle: 60° solid cone. Suitable fuels: diesel (EN 590), heavy oil (ISO 8217), biodiesel. Core functions: efficient combustion control, pressure regulation and stability, safety and reliability.
Steinen oil mouth 1.25 60°S 1.25 60°S:A solid cone atomization nozzle designed for medium and high load fuel combustion systems. This model achieves efficient atomization and stable combustion of fuel through precision cold forging technology and stainless steel material. It is widely used in industrial boilers, furnaces, ship auxiliary machines and other equipment. Traffic: 1.25 GPH. Spray angle: 60° solid cone. Working pressure: inlet 1.0-1.4MPa; outlet 5-15mbar. Suitable fuels: diesel (EN 590), heavy oil (ISO 8217), biodiesel. Core functions: efficient combustion control, pressure regulation and stability, safety and reliability.
SUNTEC oil pump AS47A 7432-4 AS47A 7432-4:It is an internal meshing gear pump designed by SUNTEC, France, for small and medium fuel combustion systems, and belongs to the AS series standard model. This product realizes stable delivery and precise control of fuel through built-in solenoid valves and pressure adjustment modules, and is widely used in industrial boilers, hot air furnaces and burner equipment. Traffic: 47 L/h (12.4 GPH) Working pressure: inlet 8-20 bar; outlet 7-14 bar. Applicable fuels: diesel (EN 590), biodiesel (B10), kerosene. Interface specifications: Oil inlet/return port: G1/4 thread; nozzle outlet: G1/8. Core functions: efficient fuel delivery, intelligent pressure control, safety and reliability. Typical application scenarios: Burner equipment: adapted to small and medium-sized burners such as RIELLO RL70, BALTUR G30, etc.
SUNTEC Oil pump CJM6AB(1000-4Z)
SUNTEC Oil pump CJM6AB(1000-4Z) CJM6AB (1000-4Z) is an internal meshing gear pump designed by SUNTEC, France, for small and medium-sized fuel combustion systems. This model achieves stable fuel delivery and precise control through the combination of precision gear pairs and pressure adjustment modules. It is widely used in industrial boilers, hot air furnaces and burner equipment. Flow: 6 L/min (360 L/h) Working pressure: Inlet 10-30 bar; outlet 12 bar. Applicable fuels: diesel (EN 590), biodiesel (B10), kerosene. Interface specifications: Oil inlet/return port: G1/4 thread; nozzle outlet: G1/8. Core functions: efficient fuel delivery, intelligent pressure control, safety and reliability. Typical application scenarios: Burner equipment: adapted to small and medium-sized burners such as RIELLO RL70, BALTUR G30, and NOx emissions can be controlled below 150ppm.
Fireye controller SB560322AA SB560322AA is an ultraviolet flame detection controller specially used for boiler burner systems. It adopts a vertical structure design. The core function is to monitor the flame status in real time through ultraviolet (UV) detection technology to ensure the safe and stable operation of combustion equipment. Main features one. Application scenarios: Suitable for gas/oil and gas burner systems, integrated into industrial boilers and other equipment, providing high-precision flame detection. two.Technical Design Vertical structure, adapted to standard burner installation requirements, has anti-interference ability and stability. three.Safety control Automatically verify the existence of the flame to prevent accidental fire out, support fault diagnosis function, and improve combustion efficiency and safety. Extended features It can work in conjunction with other Fireye combustion controllers (such as 45UV5 and 55UV5 series) to achieve more complex automation control of combustion systems. Typical operating voltage is 120V or 240V AC, compatible with 50/60Hz power supply, adapting to industrial environment needs.
Fireye controller base 61-6990-2(SB22194)
Fireye controller base 61-6990-2(SB22194) 61-6990-2 (SB22194) is a mounting base specially designed for Fireye series combustion controllers. It is mainly used to fix and connect flame detectors or combustion controllers to ensure the stable integration and signal transmission of the equipment in industrial combustion systems. Core functions one.Electrical connection and protection Terminal interface: Built-in multiple sets of wiring terminals, which can connect fuel valve control lines, flame sensor signals, power inputs, etc. to ensure stable signal transmission. Protection level: The enclosed design provides basic dust and moisture resistance, which is suitable for long-term use in industrial environments. Anti-interference: Reduce electromagnetic interference through reasonable circuit layout and ensure reliable communication between the controller and external devices. two.Mechanical Support and Compatibility Modular adaptation: Directly compatible with Fireye SB series controllers such as SB560322AA, supports plug-and-play installation without additional tools. three. System integration and scalability Expansion capability: Supports use with external terminal expansion base (such as SB22195) to meet the multi-loop control needs of complex systems. Application scenario: As a supporting base for Fireye SB series controllers (such as SB560322AA), it is used to connect external equipment such as burners, fuel valves, sensors, etc., and is suitable for gas, fuel or mixed fuel combustion systems.
Fireye fire detection eye UV7R4
Fireye fire detection eye UV7R4 UV7R4 is an ultraviolet flame detector specially designed for gas/fuel burners. It adopts a 90° right-angle structure. The core function is to monitor the flame status in real time through high-sensitivity ultraviolet (UV) sensing technology to ensure the safe operation of industrial combustion systems. Main features one. Flame monitoring: Detecting the ultraviolet rays generated by the flame burning 185-260nm, which is highly responsive to the rapid start-stop cycle of gas or fuel flames. Built-in fault detection mechanism, automatically checks the probe short-circuit or "out of control" status at the beginning and end of each flame cycle. two.Structural Design: 90° right-angle probe design, suitable for installation environments of narrow or special angles. 1830mm unshielded wire is standard and supports reverse connection protection. Installation Flexibility: 1/2" NPT threaded connector adapts to standard piping accessories, adjusting installation angles to optimize flame monitoring field of view. Applicable temperature: -40°C to 85°C. Core functions: flame detection and signal output, anti-interference and reliability design, system integration and compatibility. Application scenarios: Scenarios where industrial boilers, gas burners, etc. require high-frequency ceasefire monitoring. Can be used with Fireye multi-burner control systems (such as MB series) or single-burner control modules (such as SB series).
Azbil flame probe AUD15C1000 AUD15C1000 is an ultraviolet flame detector developed by AZBIL in Japan. It is specially used for flame monitoring of fuel/gas burners, and has high environmental tolerance and safety self-test functions. Core functions one.UV flame detection The flame is detected through the 185-260nm ultraviolet band, and is adapted to combustion equipment that operates intermittently, with fast response and strong anti-interference. two.Safety Control It is linked with dedicated controllers (such as AUR300C/AUR400C series), supports dynamic self-test function, and diagnoses probe faults in real time (such as short circuit or signal abnormality). three. Environmentally resistant design It withstands up to 120℃ high temperature, IP65 protection level, suitable for outdoor or high dust environments. Technical Features Compatibility: It must be used with a special base (such as AUD100C1000), and supports wire type (AUD100) or terminal type (AUD110). Application scenarios: Flame monitoring systems that require explosion-proof design, such as industrial boilers, gas burners, etc.