Weishaupt burner ion line

Weishaupt burner ion line Burner ion line is a key component for flame detection and is usually used in conjunction with ionizing electrodes (flame sensors). It determines whether the flame exists by detecting the ionization current of the flame during combustion to ensure the safe operation of the burner. Main functions ‌one.Flame Detection‌ When burning, the flame generates a weak ionization current, and the ion wires transmit this signal to the programmer (such as W-FM25 V2.0). The program controller determines whether the flame is burning normally by analyzing the current magnitude. ‌two.Safety protection‌ If the flame goes out unexpectedly (such as gas interruption, strong air interference, etc.) and the ion line cannot detect the current, the program controller will immediately cut off the gas supply to prevent the risk of gas leakage or explosion. ‌three.Compatibility‌ Suitable for mainstream burner brands such as Weishaupt, Riello, Baltur. Structural characteristics of ion wires: ‌Conductor: Usually high-temperature resistant copper core wire is used to ensure stable signal transmission. ‌Insulation layer‌: High temperature resistant silicone or ceramic material to prevent high temperature damage. ‌Shielding layer‌: Some models have metal shielding layers to reduce electromagnetic interference (EMI). ‌Connection terminal‌: Standard plug or screw terminal for easy connection of program controller or electrodes.

Weishaupt burner LCD display AM25 V1.0(D-73660)

Weishaupt burner LCD display AM25 V1.0(D-73660) AM25 V1.0 (D-73660)‌ is a ‌LCD display (LCD) module designed for burner control systems. It is usually used with Wisso Programming Controllers (such as W-FM25 V2.0) for human-computer interaction, parameter setting and operating status monitoring. ‌Supply voltage: 24V DC (usually provided by the program controller) ‌Protection Level‌: IP40 (dust-proof, not waterproof) Main functions ‌(1) Operation status display Display the burner operation mode‌‌ in real time (standby, ignition, operation, fault, etc.). Displays the flame status (with/no fire), temperature/pressure value (such as boiler water temperature, flue gas temperature, etc.). Provide ‌fault codes‌ (such as E01 ignition failure, E02 ignition shutdown, etc.) to facilitate rapid diagnosis of problems. ‌(2) Parameter setting and debugging ‌ Adjust burner parameters by pressing the keys, such as: ‌ignition time‌‌ pre-purging time‌ ‌Gas valve opening‌ (proportional adjustment burner) Temperature/pressure setting value Supports ‌manual/automatic mode switching, which is convenient for maintenance and testing. ‌(3) Security and Alarm Management Automatically record the fault history to help analyze burner operation problems. ‌(4) Communication interface ‌ Communication with the host computer (PLC, building control system) through ‌eBUS or Modbus, realizing remote monitoring and data transmission.

Ecoflam lpg conversion kit

Ecoflam lpg conversion kit An LPG conversion kit is a dedicated component used to convert natural gas (NG) burners to operate on liquefied petroleum gas (LPG), suitable for Ecoflam series burners such as MAX GAS and BLU series. This kit includes necessary hardware and adjustment parts to ensure the burner remains efficient, safe, and low-emission after fuel switching. Main functions: Fuel switching adaptation: Convert the burner from natural gas (NG) mode to liquefied petroleum gas (LPG) mode. Combustion parameter optimization: Adjust gas pressure and air-fuel ratio to ensure combustion efficiency. Safety protection: Prevent risks such as backfire and explosion due to differences in fuel characteristics. Compatibility: Applicable to multiple Ecoflam burner models. Gas pressure adjustment: The operating pressure of LPG is usually higher than that of natural gas. Gas pressure regulating valve: Adjust the inlet pressure to the LPG applicable range (typically 30-50 mbar). Gas valve assembly adjustment parts: May include springs, diaphragms, etc., to optimize valve response.

RIELLO ignition rod RS5~BS4-M (3008932)

RIELLO ignition rod RS5~BS4-M (3008932) RS5~BS4-M is the core ignition accessories specially designed by the Italian RIELLO brand for industrial burners, and is suitable for BS4/RS5 series combustion equipment. Suitable gas types: natural gas (G20-G25), liquefied gas (LPG). Working voltage: 230V AC ±10%, 50/60Hz. Core functions ‌one.Stable ignition‌ It uses high-temperature resistant ceramic material (working temperature up to 90℃) to ensure long-term and stable work in industrial-grade combustion environments, and is suitable for fuel systems such as natural gas and liquefied gas. ‌two.Safety Test‌ Integrated ion probe function can monitor flame status in real time, and be linked to the burner control system to achieve flame out protection. ‌three.Various compatibility Supports RS5/RS5D, BS4/BS4D and other series of combustion heads, suitable for boilers, hot air furnaces and thermal oil furnaces in the power range of 45-2650kW. Application scenarios Ignition and flame monitoring of industrial boilers and hot air furnaces. A combustion system that requires proportional adjustment or two-stage fire control.

RIELLO silent box C7

RIELLO silent box C7 The Silent box C7 is a noise reduction component designed for Riello burners. It is mainly used to reduce noise pollution caused by burners during operation, especially for environmental noise-sensitive scenarios (such as residential areas, hospitals or commercial complexes). Gas types: natural gas (G20-G25), liquefied gas (LPG) and light oil (FO). Burner models: Gulliver BS4/M, RS5; RLS 68/M MX, RLS 120/M MX, etc. Core functions ‌one.Industrial noise reduction‌ It adopts a multi-layer sound-absorbing structure (metal shell + sound-insulating cotton) to effectively reduce the mechanical noise generated during the operation of the burner. ‌two.Environmental adaptation design‌ Built-in ventilation and cooling system ensures that the combustion equipment maintains a safe temperature while operating normally in confined spaces. ‌three.Modular installation‌ Adaptable to RIELLO RS5/BS4 series burners, supports quick disassembly and maintenance, and is used in conjunction with ignition rods and other accessories. Protection level: IP54 (dust-proof and waterproof) Application scenarios Industrial environment noise control such as boiler rooms and hot air furnaces. A place with strict requirements for working environment noise.

RIELLO copper tube 2G (3006738)

RIELLO copper tube 2G (3006738) Copper tube 2G is a precision accessories for gas/fuel delivery in Riello burner systems. It is mainly suitable for Gulliver series burners (such as BS4/M, RS5 and other models) and some RLS models. Suitable media: natural gas, liquefied gas, light oil. Working pressure: ≤1.6MPa (gas) / ≤2.5MPa (fuel). Core functions ‌one. Industrial grade high temperature resistance It is made of T2 copper material (copper content ≥99.9%), and the working temperature can reach above 300℃. It is suitable for fuel delivery systems such as natural gas/liquefied gas. ‌two.Precision fluid transmission‌ Seamless process manufacturing, with the inner wall smoothness Ra≤6.3μm, ensuring stable fuel delivery without residue‌. ‌three.System compatibility‌ Designed specifically for RIELLO burners, it works in conjunction with components such as ignition rods, silent boxes, etc., and supports pipeline connections of 2G series combustion equipment. Application scenarios Industrial boiler gas delivery pipeline. Central air conditioning refrigerant circulation system‌. Hydraulic signal transmission that is resistant to high pressure (≤3MPa) is required.

SIEMENS comparison instrument RWF50.20A9

SIEMENS comparison instrument RWF50.20A9 Comparison instrument RWF50.20A9RWF50.20A9‌ is a digital proportional regulator specially designed for industrial burners. It belongs to the Siemens RWF50‌ series of products and is mainly used for temperature or pressure control of boilers, hot air furnaces and other equipment. Input voltage‌: AC 100V–240V ±10%, 50/60Hz‌. ‌Output Form‌: 3-bit relay output (increase/decrease control). ‌Protection Level‌: IP65 (dust-proof and waterproof). ‌Operation temperature‌: -20℃ to +50℃‌. Main functions o‌ne.PID Intelligent Adjustment‌ Through the digital PID control algorithm, the air-fuel ratio of the burner is adjusted in real time and the combustion efficiency is optimized. ‌two.Two section fire control‌ It supports two-stage combustion mode, can automatically switch small fire/high fire operation according to needs, and control the actuator through relay output. ‌three.Status display and monitoring‌ Two-color LED display: green displays the set value, red displays the measured value‌. The burner damper position, pulse signal and working status (on/off, 1st section fire/2nd section fire) are fed back in real time through the indicator light. ‌four.Automatic adjustment function‌ It can automatically determine PID adjustment parameters to simplify the debugging process‌. Application scenarios‌ Combustion control of industrial boilers and thermal oil furnaces‌. Gas/fuel systems that require proportional adjustment or two-stage fire control‌.

RIELLO combustor accessories seven-hole socket

RIELLO combustor accessories seven-hole socket Combustor accessories seven-hole socket is a core electrical connection component specially designed for industrial burners, mainly used to control signal transmission and power supply of equipment. Rated current: 10A (standard load) ‌Protection Level‌: IP65 (dust-proof and waterproof) ‌Working temperature‌: -20℃ to +150℃. Core functions‌ ‌one.Multi-channel signal transmission‌ As a key interface of the burner control system, it supports 7-pin connection (including power supply, ignition signal, damper control, etc.), realizing coordinated work with components such as the proportional regulator, pressure switch, etc. ‌two.High reliability design‌ It uses high-temperature resistant materials (such as ceramic insulators) to adapt to voltage fluctuations (220V/380V) and frequent plug-and-removal requirements in industrial environments‌. ‌three.Modular compatibility‌ Matched with burners such as RIELLO RS series, Gulliver RG series, etc., and directly connect to the control box (such as RM088.53 model) to complete circuit integration‌. Application scenarios‌ Boiler room burner circuit control. Industrial thermal equipment that requires remote signal transmission.

DUNGS valve body motherboard(263636)

DUNGS valve body motherboard(263636) Valve body motherboard:is a valve body motherboard (main control module) used in gas control systems. It is usually used in conjunction with ‌DUNGS solenoid valves (such as MBC, MB series) and is suitable for industrial or commercial gas burners, boilers and gas regulation systems. The motherboard is responsible for controlling the switch, safety monitoring and fault protection of the solenoid valve to ensure the stable operation of the gas system. Main functions Solenoid valve control: drive and monitor dual solenoid valves (such as DN15-DN50 specifications) to ensure safe gas on and off. ‌Safety Protection‌: It has ‌flame monitoring, pressure detection, valve leakage detection (optional)‌ functions, and complies with EN 161 and other safety standards. ‌Fault Diagnosis‌: Provide ‌LED indicator lights or fault codes‌ to facilitate troubleshooting solenoid valve failures (such as coil open circuit, short circuit, valve jamming, etc.). ‌Compatibility‌: Adapt to DUNGS solenoid valves (such as MB/MBC series), supporting 230V AC or 24V DC power supply (depending on model). ‌Quick Response‌: Supports quick turn-off (<1s) and on (<20s), suitable for high dynamic gas regulation systems. Supply voltage: 230V AC (±10%), 50/60Hz or 24V DC. ‌Protection Level‌: IP54/IP65 (dust-proof and waterproof). ‌Operating temperature‌:-15°C ~ +70°C. Suitable for gas: natural gas, liquefied gas (LPG), urban gas, etc. Typical Application ‌Commercial/Industrial Burner‌ (boilers, hot air furnaces, drying equipment, etc.). ‌Gas pressure regulation system‌ (used in conjunction with DUNGS pressure regulator). Safe cut-off system (such as gas leakage protection, flame failure protection).

DUNGS pressure sensor PS-50-200

DUNGS pressure sensor PS-50-200 PS-50-200‌ is a high-precision gas pressure sensor, which is mainly used to monitor the gas pressure in gas pipelines (such as natural gas, liquefied gas, etc.) and convert the pressure signal into electrical signals (such as 0-10V, 4-20mA or switching signal) for output, for adjustment and protection by combustion control systems or PLC. ‌Measurement range‌: 50~200 mbar. ‌Output signal‌: 0-10V / 4-20mA / Relay switch quantity. ‌Supply voltage: 24V DC or 230V AC. ‌Accuracy‌:±1% FS (full scale). ‌Medium temperature‌:-10°C ~ +70°C (suitable for conventional gas). ‌Protection Level‌: IP65 (dust-proof and waterproof). ‌Interface Dimensions‌: G¼ / G½ internal thread (or other standard interface) ‌Material‌:Aluminum alloy/stainless steel (corrosion-resistant). Main functions Pressure monitoring: Real-time detection of gas pressure. ‌Signal Output ‌: Provides analog (such as 0-10V / 4-20mA) or switching (relay) ‌ signals for easy integration into the control system. ‌Safety Protection‌: Trigger alarm or cut off gas supply when pressure is abnormal (too high/too low), preventing equipment damage or safety accidents. ‌High precision & stability‌: Use high-sensitivity sensing elements, good long-term working stability and strong anti-interference ability. ‌Compatibility‌: Suitable for DUNGS gas control systems (such as MBC series solenoid valves, gas pressure regulators, etc.).

DUNGS motherboard 1511-2P-1711-2P(263636)

DUNGS motherboard 1511-2P-1711-2P(263636) 1511-2P / 1711-2P (263636)‌ is an electronic control motherboard for gas combustion control systems. It is usually used in conjunction with ‌DUNGS solenoid valves (such as MB/MBC series)‌ and is suitable for gas equipment such as industrial burners, boilers, hot air furnaces. This motherboard is responsible for solenoid valve drive, safety monitoring, and fault diagnosis to ensure the stable operation and safety protection of the gas system. Supply voltage: 230V AC (±10%), 50/60Hz or 24V DC. ‌Output Control‌: Dual solenoid valve (2P) drive. ‌Protection Level‌: IP54/IP65 (dust-proof and waterproof). ‌Operating temperature‌:-15°C ~ +70°C. Main functions ‌Solvent control‌: drives dual solenoid valves (2P means dual valve control)‌ to ensure safe gas on and off. ‌Safety Monitoring‌: ‌Flame Detection‌ (optional, need to be equipped with an ionizing electrode or UV sensor) Pressure monitoring (such as gas pressure is too high/too low protection) ‌Valve Leak Detection (Optional): Detection of Solenoid Valve Leakage ‌Troubleshooting‌: ‌LED indicator light or fault code‌ (such as open circuit, short circuit, stuck, etc.) ‌Auto lock protection‌(Shut off gas in case of failure) ‌Compatibility‌: Adapt to DUNGS ‌MB/MBC series solenoid valve‌, supporting ‌230V AC or 24V DC‌ power supply.

DUNGS motherboard Art.Nr210164 (222941B)

DUNGS motherboard Art.Nr210164 (222941B) Art.Nr 210164 (222941B)‌ is an electronic control motherboard used for gas combustion control systems. It belongs to the DUNGS solenoid valve drive and safety monitoring module series. This motherboard is usually used in conjunction with the DUNGS MB/MBC series solenoid valves. It is suitable for gas equipment such as industrial burners, boilers, hot air furnaces, and provides solenoid valve drive, safety monitoring and fault protection functions. Main functions ‌Solvent valve control‌: drive single/double solenoid valves (depending on the specific model) to ensure safe gas on and off. ‌Safety Monitoring‌: ‌Flame Detection‌ (need to be equipped with an ionizing electrode or UV sensor) Pressure monitoring (such as gas pressure is too high/too low protection) ‌Valve Leak Detection: Detection of Solenoid Valve Leakage ‌Troubleshooting‌: ‌LED indicator light or fault code‌ (such as open circuit, short circuit, stuck, etc.) ‌Auto lock protection‌(Shut off gas in case of failure) ‌Compatibility‌: Adapt to DUNGS ‌MB/MBC series solenoid valve‌, and supports ‌230V AC or 24V DC‌ power supply (depending on the specific model). Protection level: IP54 / IP65 (dust-proof and waterproof) ‌Operating temperature‌:-15°C ~ +70°C. Typical applications: industrial burners, gas safety control systems (used in conjunction with DUNGS pressure regulating valves and pressure sensors).

DUNGS motherboard Nr.1511-1811-2P DC(257604)

DUNGS motherboard Nr.1511-1811-2P DC(257604) 1511-1811-2P DC (257604)‌ is an electronic control motherboard designed for gas combustion systems. It belongs to the DUNGS solenoid valve drive and safety control module series. The motherboard is powered by DC and is mainly used to control dual solenoid valve (2P) systems. It is suitable for industrial combustion equipment that requires high safety gas control. ‌Supply voltage‌: 24V DC (±15%). ‌Power consumption‌: Maximum 15W. ‌Output Control‌: Dual Solenoid Valve Drive (2P). ‌Protection Level‌: IP54. ‌Operating temperature‌:-20°C ~ +60°C. ‌Solbar compatibility‌:MB/MBC series. ‌Interface type‌: Screw terminal. Main functions ‌Double Solenoid Valve Control (2P): Independently control two solenoid valves in series, providing valve inspection function to ensure that the valve is completely closed. ‌Safety Monitoring and Protection‌: Flame monitoring (needed to be combined with ionizing electrodes or UV sensors) Pressure monitoring interface (can be connected to DUNGS pressure sensor) Valve leak detection function ‌Troubleshooting and protection‌: LED status indicator displays operation/fault status Automatic lock protection function (disconnect gas supply in case of failure) Supports manual reset compatibility: Designed for DUNGS MB/MBC series solenoid valves Integrate with other DUNGS security components ‌Typical Application‌: Industrial combustion systems (boilers, hot air furnaces, furnaces, etc.) Commercial gas equipment (food processing, drying system) Gas applications requiring high safety control.

SIEMENS servo motor SQM56.687A1

SIEMENS servo motor SQM56.687A1 SQM56.687A1‌ is a high-performance AC servo motor, belonging to the SQM5 series electric actuators, mainly used for gas/air valve control and damper adjustment in industrial combustion systems. The motor adopts ‌Permanent Magnet Synchronous Motor (PMSM)‌ technology, and has the characteristics of ‌high dynamic response, low moment of inertia, high torque density‌. Supply voltage: AC 110V±10% (50/60Hz), power consumption is about 20VA, built-in overcurrent protection (trip current 3A). Protection level: IP54 (dust-proof and splash-proof). Power output: Directly drive mechanical loads (such as valve shaft). Control target: Adjust the angle position or opening of the valve/storm. Core functions: precision control of combustion system, intelligent diagnosis and maintenance support, communication and expansion capabilities. Application scenarios: industrial valve control, combustion system adjustment.

SIEMENS servo motor SQM48.497B9

SIEMENS servo motor SQM48.497B9 SQM48.497B9 belongs to the SQM48 series electric actuators, mainly used for gas/air valve control and damper adjustment in industrial combustion systems. Running time: 30 seconds / 90° (AC 2x12V powered), supports speed adjustment through the burner controller (such as 60 seconds / 90° mode). Torque output: 20N・m (continuous load), peak torque can reach 20N・m, suitable for medium and high resistance valve drives. Supply voltage: AC 2x12V±10% (50/60Hz), power consumption is about 26-34VA, built-in overcurrent protection (trip current 3A). Protection level: IP54 (dust-proof and splash-proof), optional IP65 upgraded version, suitable for humid or dusty environments. Mechanical interlock: Manual/automatic switching clutch allows manual operation of the valve with special tools during power outage to avoid control failure in emergencies. Overload protection: Built-in torque limiter, which automatically disengages when the load exceeds the set value (such as valve jams), prevents the motor from burning. Control target: Adjust the angle position or opening of the valve/storm. Core functions: precision control of combustion system, intelligent diagnosis and maintenance support, communication and expansion capabilities. Application scenarios: industrial valve control, combustion system adjustment.

< 1...192021...25 >